522 CMR, § 7.01 - Scope
In accordance with the provisions of M.G.L. c. 146, § 2, the Board adopts by reference the 2021 ASME Boiler and Pressure Vessel Code Section VIII, Rules for Construction of Pressure Vessels.
(1) 522 CMR 7.00
shall apply to all Air Tanks enumerated in M.G.L. c. 146, § 34, including:
Air Tanks that meet the following criteria:
(a) design MAWP greater than 50
PSI;
(b) greater than six inches
internal diameter; and
(c) internal
volume greater than one cubic foot.
Note: The exemption of Air Tanks containing less than one cubic foot of air applies to each single vessel and not to an assembly of vessels.
(2) 522 CMR 7.00 shall not apply to the
exceptions enumerated in M.G.L. c. 146, § 34, including the following:
(a) Air Tanks subject to Federal
control.
(b) Air Tanks attached to
locomotives, street cars, railway cars, trackless trolley vehicles, or to motor
vehicles for use in operating such vehicles or their brakes or body lifting
apparatus.
(c) Air Tanks in which
air is used solely for cushioning systems containing water or other
liquids.
(d) Air Tanks containing
air and liquids in which the pressure is maintained by pumps, for example,
hydraulic elevator tanks.
(e) An
Air Tank or other receptacle used by divers if such Air Tank or other
receptacle is inspected by the refilling agency.
(f) Portable tanks and bottles containing
compressed air as used for breathing purposes while combating fires or used in
rescue operations in contaminated areas; and storage tanks and mechanical
filling systems used to fill such portable tanks and bottles.
(g) Air Tanks used in and as part of
electrical substations owned and operated by an electric company, as defined
M.G.L. c. 164, § 1.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.