Minn. R. agency 151, ch. 1305, pt. 1305.1510 - SECTION 1510, REROOFING
IBC Section 1510.5 is amended to read as follows:
1510.5
Reinstallation of
materials. Existing slate, clay or cement tile shall be permitted for
reinstallation, except that damaged, cracked or broken slate or tile shall not
be reinstalled. Existing vent flashing, metal edging, drain outlets, collars
and metal counterflashings shall not be reinstalled where rusted, damaged or
deteriorated. Aggregate surfacing materials shall not be reinstalled unless
such aggregate complies with the gradation requirements of ASTM C-33 Standard
Specification for Concrete Aggregate.