Mont. Admin. r. 38.4.411 - SIDE CLEARANCE - BRIDGES AND TUNNELS
(1) The
minimum side clearance for bridges and tunnels is eight (8) feet.
(2) For required clearance of upper section
of bridges and tunnels see ARM
38.4.406.
(3) Side clearance in through bridges and
tunnels may be decreased to the extent defined by the half circumference of a
circle having a radius of eight (8) feet and tangent to a horizontal line
twenty-two (22) feet six (6) inches above top of rail directly above centerline
of track.
(4) Bridges--Lower
section and structures four (4) feet high or less. Through bridges supporting
track affected, hand rails, water barrels and refuge platforms on bridges and
trestles, water columns, oil columns, block signals, cattle guards and cattle
chutes, or portions thereof, four (4) feet or less above top of rail may have
clearances decreased to the extent defined by a line extending diagonally
upward from a point level with the top of rail and five (5) feet distant
laterally from centerline of track to a point four (4) feet above top of rail
and eight (8) feet distant laterally from centerline of track: Provided that
the minimum clearance for hand rails and water barrels shall be seven (7) feet
six (6) inches and the minimum clearance for fences of cattle guards shall be
six (6) feet nine (9) inches.
(5)
Clearances authorized in (4), except as provided for hand rails and water
barrels, shall not be permitted on any new or entirely reconstructed through
bridges where the work of trainmen or yardmen requires them to be upon the
decks of such bridges for the purpose of coupling or uncoupling cars in the
performance of switching service on a switching lead.