N.J. Admin. Code § 13:20-53B.7 - Automatic pressure reducing regulators
(a) An automatic
pressure reducing regulator or regulators shall be installed in every CNG system to
reduce fuel supply container pressure to a value consistent with the working
pressure required by the carburetor. Means shall be provided to prevent regulator
malfunction due to refrigeration effects.
(b) Every automatic pressure reducing regulator
shall be installed so that its weight is not placed on, or supported alone by, the
attaching line or lines.
(c) Every
automatic pressure reducing regulator shall be designed to the CNG fuel supply
container's maximum working pressure and temperature with a pressure safety factor
of not less than four.