N.J. Admin. Code § 13:20-53C.8 - Gauges

(a) Gauges used in LNG systems shall be designed and installed as follows:
1. Gauging devices shall be designed for the most severe pressure and temperature conditions to which the devices may be subjected with a pressure safety factor of not less than four;
2. Gauges shall be securely mounted and shielded or installed in protected locations to prevent damage from excessive vibration or unsecured objects; and
3. A gauging device that requires bleeding of the product shall be equipped with a bleeder valve and the product shall be bled to the outside of the school bus passenger compartment.