N.Y. Comp. Codes R. & Regs. Tit. 12 § 21.7 - Working from ladders
(a)
Use of method. The use of this method is prohibited for cleaning a window where
any of the following conditions exist:
(1) The
interior surface of the window is to be cleaned and the top of such window is
more than 35 feet above the nearest interior floor or equivalent surface on
which the base of the ladder is to be placed.
(2) The exterior surface of the window is to
be cleaned and the top of such window is more than 35 feet above the nearest
street or ground surface.
(3) The
window is so placed or obstructed as to make the method unsafe.
(b) Ladders over 18 feet--holding.
At all times when a cleaner is working on a ladder over 18 feet long, a person
shall stand at the foot of it, face it and hold it with both hands.
(c) Sidewalk doors. No ladder shall be rested
on a sidewalk door.
(d) Protection
against slipping. All ladders shall be provided with means to prevent slipping
suitable to the bearing surface.
(e) Inspection of ladders. Each ladder shall
be inspected at least once a month by the person who owns it.
(f) Painting of wood ladders. A wood ladder
shall not be painted with other than a transparent material.
(g) Maintenance and replacement. Ladders
shall at all times be maintained in a safe condition. Any ladder having a
broken member or part, or any insecure joint between members or parts or any
flaw or defect of material that may cause failure, or any rung or step that is
worn down to three quarters or less of its original thickness, shall be
immediately taken out of service for necessary repairs or
replacement.
(h) Strength. Ladders,
including all load-bearing parts and connections, shall be designed and
constructed to sustain without failure a concentrated load of not less than 600
pounds.
(i) Wood ladder
construction. Wood used in the construction of ladders shall be thoroughly
seasoned, sound, clear and straight-grained and the slope of the cross grain
shall not exceed one in 15 at any point for rungs, steps or cleats, and shall
not exceed one in 12 for rails. Wood used in side rails shall be at least
equivalent in strength and durability to Sitka spruce. Rungs shall be of
commercial white ash, white oak or hickory. Load-bearing metal parts shall be
of steel, wrought iron, malleable cast iron or other metal of equivalent
strength and durability.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.