(a)
Each machine source of ionizing radiation, and each generally licensed device
so required by the terms and conditions of Table 3 of section
38.41 of this Part (rule) shall be
registered with the commissioner on a form prescribed by him or her, setting
forth the location and character of the radiation source or sources and such
other or further information as he or she may require for the due enforcement
of this Part (rule). Registration shall be made prior to receipt of the
radiation equipment or upon receipt of the generally licensed device.
Registration is not complete until it is verified and accepted by the
commissioner. If a registered installation is so changed as to render its
registration inaccurate, notice thereof shall be given to the commissioner
within 48 hours of such change.
(b)
Every distributor or retailer of radiation equipment, or agent thereof, or
radiation consultant, who installs, tests or otherwise services radiation
equipment shall be registered with the commissioner on a form prescribed by
him. Registration shall be made prior to undertaking such installation, testing
or servicing. Such distributors, retailers, agents or consultants shall, while
engaged in installation, testing or other servicing of radiation equipment,
comply with the requirements of this Part (rule).