N.Y. Comp. Codes R. & Regs. Tit. 12 § 47.11 - Replacement and new installations
(a) Any transparent glazing material used for
replacement in existing transparent glass doors after January 1, 1968 shall be
transparent safety glazing material. Transparent safety glazing material shall
be used in all new transparent glass doors installed after January 1, 1969. The
manufacturer's permanent identification mark denoting safety glazing material
shall be visible on the glass after installation of the door.
(b) Replacement of fixed adjacent transparent
glass sidelights after January 1, 1968 shall be of transparent safety glazing
material or annealed glass at least one-half inch in thickness. New fixed
adjacent transparent glass sidelights installed after January 1, 1969 shall be
of transparent safety glazing material or annealed glass at least one-half inch
in thickness. The manufacturer's permanent identification mark denoting safety
glazing material shall be visible on the glass after installation of the
sidelight.
Notes
If safety glazing material is not immediately available as replacement glass in transparent glass doors and fixed adjacent transparent glass sidelights, temporary relief from the requirements of section 47.11 of this Part (rule) may be sought by petitioning the Board of Standards and Appeals for a variation in accordance with section 30 of the Labor Law of New York State.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.