N.Y. Comp. Codes R. & Regs. Tit. 12 § 50.13 - Special precautions
(a) No
individual shall look directly into a primary laser beam or directly at the
specular reflections of such a beam when the intensities of such beam or of
such reflections are greater than those listed in Table 1 of this Part (rule),
unless such individual is wearing approved eye protection in compliance with
the provisions of this Part (rule).
(b) Every laser beam shall be terminated
whenever necessary by a material that is non-reflecting and fire-retardant. In
cases of intentional beam interaction with targets, precautions shall be taken
to prevent fires arising from flying particles. In cases of unavoidable
reflections, precautions shall be taken to prevent the scatter of laser
radiation in excess of the limits listed in this Part (rule) into uncontrolled
areas.
(c) Under circumstances
where the conditions of laser operation can lead to accidental exposure to
laser radiation above the maximum permissible exposure limits as specified in
this Part (rule), an area shall be cleared of all individuals for a reasonable
distance on all sides of the anticipated path of the laser beam, except for
those individuals protected in compliance with the provisions of this Part
(rule).
(d) Special care shall be
taken to assure that approved safety eyewear is matched to the specific wave
length of the laser device with which it is to be used and that such eyewear
provides the required attenuation.
(e) Any approved safety eyewear which has
been exposed to high-intensity laser radiation shall not be reused until it has
been reevaluated for shattering and effectiveness of its attenuation.
(f) Laser beam paths shall be cleared of all
material or objects that may cause the scatter of laser radiation at levels in
excess of the limits listed in this Part (rule) into uncontrolled
areas.
(g) All unshielded lasers
which are capable of emitting radiation above the maximum permissible exposure
limits as listed in this Part (rule) shall be capped or otherwise effectively
terminated when not in operation.
(h) Interlocks used on enclosures for
high-intensity lasers shall not be used to actuate such lasers.
(i) Any closed laser installation with one or
more access openings large enough for entry by individuals shall have at least
one such opening provided with an exit door which can be manually opened with
ease from inside the laser installation.
(j) General illumination in laser radiation
areas shall be at least 30 lumens per square foot, except where conditions of
laser operation require lower ambient illumination.
(k) Electronic firing systems for pulsed
lasers shall be so designed that accidental discharges of stored charges are
prevented.
(l) "Fail-safe" safety
circuitry shall be used with lasers wherever necessary.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.