13 N.C. Admin. Code 07F .0714 - MISFIRES
Additions and amendments to 29 CFR 1926.911 Misfires apply throughout the Rules in this Section as follows:
(a) If a
misfire is found, the Blaster-in-Charge shall invoke sufficient safeguards to
exclude all employees from the potential blast area.
(b) No work shall be done except that
necessary to remove the hazard of the misfire. Only those employees necessary
to do the work shall enter the potential blast area. Only the
Blaster-in-Charge, and the absolute minimum number of competent, personnel (as
defined in 29 CFR 1926 Subparts Land P), necessary to assess the situation
shall approach the hole to inspect the misfire.
(c) The Blaster-in-Charge shall determine the
safest steps for removing the hazard of the misfire. During development and
implementation of these steps, the Blaster-in-Charge shall comply with the
manufacturer's recommendations. Further, the guidelines of the Safety in the
Transportation, Storage, Handling and Use of Explosive Materials, IME Safety
Library Publication No. 17, which is incorporated herein by reference,
including any subsequent amendments and editions, shall be utilized.
(d) If there are any misfires while using
safety fuse and blasting cap, all employees shall remain out of the potential
blast area for at least 30 minutes. If electric detonators, shock tube, gas
tube or detonating cord systems or materials were used and a misfire occurred,
the waiting period may be reduced to 15 minutes. In either case, the
Blaster-in-Charge shall assess the circumstances and invoke a safe waiting
period before allowing any personnel to enter the potential blast area. All
lines shall be carefully traced and a search made for unexploded
charges.
(e) No drilling, digging,
or picking shall be permitted until all misfires have been detonated or the
Blaster-in-Charge approves the work.