Ohio Admin. Code 1301:3-4-04 - Initial certification of historical boilers
(A) Before the initial certification of
an
a
historical boiler, the boiler and its appurtenances shall be subjected to a
nondestructive design evaluation at the boiler's maximum allowable working
pressure. The maximum allowable working pressure shall be no more than the
current safety valve setting, which shall be no
more than one hundred eighty pounds per square inch. The hydrostatic test
pressure shall be one and one quarter of the safety valve setting, but in no
case greater than two hundred twenty-five pounds per square inch, except for
railway locomotives for which the safety valves may be set in accordance with
the manufacturer's specifications.
(B) Before the initial certification of
an
a
historical boiler, all historical boilers and their appurtenances shall be
inspected thoroughly, internally and externally, and under operating conditions
by inspectors designated by the chief boiler
inspector of the division of boiler
inspection
section in the division of industrial compliance in
the department of commerce. The internal and external inspection under
operating conditions shall, at a minimum, include an inspection of all of the
following:
(1) Smoke box;
(2) Barrel;
(3) Wrapper sheet;
(4) Water column and water glass;
(5) Firebox;
(6) Stays;
(7) Fusible plug;
(8) Threaded openings;
(9) Inspection openings;
(10) Pressure gage;
(11) External plumbing and piping;
(12) Injectors;
(13) Pipe schedule and valve
ratings;
(14) Tubes;
(15) Tube sheets; and
(16) Steam safety valve.
(C) During the initial certification of
an
a
historical boiler, the inspector may ultrasonically evaluate
an
a
historical boiler or any portion thereof for cause.
Notes
Promulgated Under: 119.03
Statutory Authority: 4104.34
Rule Amplifies: 4104.36
Prior Effective Dates: 05/27/2003 (Emer.), 04/30/2006, 11/30/2006
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.