Ohio Admin. Code 1501:21-13-03 - Spillway design, general requirements
(A) Every dam shall have a spillway system
which will safely operate during the design flood without endangering the
safety of the dam.
(B) Each
spillway shall include a means of dissipating the energy of flow without
endangering the safety of the dam.
(C) The capacity of the spillway system shall
be equal to the peak inflow rate of the design flood unless the applicant has
demonstrated by flood routing procedures that the dam will safely pass the
design flood with the spillway system.
(D) Every upground reservoir shall have an
overflow or other device to preclude overfilling the reservoir during normal
filling operations. Local watershed drainage into the reservoir must also be
included in the design of the overflow device if applicable.
(1) The elevation of an overflow device shall
be no more than 0.5 foot above the designed maximum operating pool level of the
reservoir.
(2) A device other than
an overflow that is used to preclude overfilling must prevent the reservoir
from rising 0.5 foot above the designed maximum operating pool level.
Notes
Promulgated Under: 119.03
Statutory Authority: 1521.06
Rule Amplifies: 1521.06, 1521.061
Prior Effective Dates: 04/15/1972, 10/15/1981, 12/09/1999, 01/16/2005
Promulgated Under: 119.03
Statutory Authority: 1521.06
Rule Amplifies: 1521.06, 1521.061
Prior Effective Dates: 04/15/1972, 10/15/1981, 12/09/1999, 01/16/2005
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.