Ohio Admin. Code 1501:21-13-12 - Design flood for levees
(A) The design flood shall be established by
the chief in concert with the applicant's desired level of protection, but with
the utmost interest in safeguarding life, health, and property. For class I
levees, the minimum design flood will be the one-hundred-year flood or the
critical flood. The design for the critical flood shall be for site-specific
conditions and based on a quantitative and relative impact analysis of the
protected area. In determining the critical flood, the levee shall be designed
so that there will be no additional potential for loss of life, health or
property from overtopping failure of the levee when compared to the potential
for loss of life, health or property caused by the flood in the absence of a
levee overtopping failure.
(B) The
magnitude of the design flood shall be determined from actual streamflow and
flood frequency records or from synthetic hydrologic criteria based on current
publications prepared by the division, the national oceanic and atmospheric
administration (NOAA), the United States army corps of engineers, the United
States geological survey, or others specifically approved by the chief.
Notes
Promulgated Under: 119.03
Statutory Authority: 1521.06
Rule Amplifies: 1521.06, 1521.061, 1521.062
Prior Effective Dates: 10/15/1981, 12/09/1999, 01/16/2005
Promulgated Under: 119.03
Statutory Authority: 1521.06
Rule Amplifies: 1521.06, 1521.061, 1521.062
Prior Effective Dates: 10/15/1981, 12/09/1999, 01/16/2005
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.