(A) No owner or operator of any coal-fired
steam generating unit greater than three hundred fifty MM Btu actual heat input
in Cuyahoga county, unless otherwise specified in this rule, shall cause or
permit the emission of sulfur dioxide from any source to exceed a maximum of
1.2 pounds of sulfur dioxide per MM Btu actual heat input.
(B) No owner or operator of any coal-fired
steam generating unit between ten MM Btu per hour and three hundred fifty MM
Btu per hour in Cuyahoga county, unless otherwise specified in this rule, shall
cause or permit the emission of sulfur dioxide from any source to exceed the
following equation:
EL = 7.014 Qm-
0.3014
where Qm is the total rated capacity of
heat input in MM Btu per hour and EL is the allowable emission rate in pounds
of sulfur dioxide per Btu actual heat input.
(C) [Reserved.]
(D) [Reserved.]
(E) [Reserved.]
(F) [Reserved.]
(G)
The "Cleveland
Thermal, LLC" (OEPA premise number 1318000246) or any subsequent owner or
operator of the "Cleveland Thermal, LLC, 2274 Canal Road, Cleveland, Ohio"
shall not cause or permit the emission of sulfur dioxide from boiler numbers
34, 35 and 37 (OEPA source numbers B101, B102, and B104) to exceed a maximum of
1.38 pounds of sulfur dioxide per MM Btu actual heat input from each
boiler.
[Reserved.]
(H) The "Cleveland Thermal, LLC" (OEPA
premise number 1318000246) or any subsequent owner or operator of the
"Cleveland Thermal, LLC, 1921 Hamilton Avenue, Cleveland, Ohio" shall not cause
or permit the emission of sulfur dioxide from boiler
numbers
number
1
, 2, 3, 5 and 6 (OEPA source
numbers
number B001
, B002, B003,
B005 and B006) to exceed a maximum of 1.0 pound of sulfur dioxide per
MM Btu actual heat input from
each
the boiler.
(I) [Reserved.]
(J) [Reserved.]
(K) [Reserved.]
(L) [Reserved.]
(M) The "NASA John H. Glenn Research Center
- Lewis Field" (OEPA premise number 1318001169)
or any subsequent owner or operator of the "NASA John H. Glenn Research Center
- Lewis Field, 21000 Brookpark Road, Cleveland,
Ohio" shall not cause or permit the emission of sulfur dioxide from the
following sources to exceed the amount indicated:
(1) Boiler numbers 1 and 2 (OEPA source
numbers B014 and B015); a maximum of 2.8 pounds of sulfur dioxide per MM Btu
actual heat input from each boiler.
(2) Boiler number 5 (OEPA source number
B005); a maximum of 1.2 pounds of sulfur dioxide per MM Btu actual heat input
from each boiler.
(N)
[Reserved.]
(O) The "ArcelorMittal
Cleveland LLC" (OEPA premise number 1318001613) or any subsequent owner or
operator of the "ArcelorMittal Cleveland LLC, 3060 Eggers Avenue, Cleveland,
Ohio" shall not cause or permit the emission of sulfur dioxide from the
following sources to exceed the maximum amounts indicated, and shall limit the
operation of said sources such that the indicated average sulfur dioxide
emission rates are not exceeded for any calendar day:
(1) Boiler numbers A, B and C (OEPA source
numbers B001, B002 and B003); a maximum of 0.99 pound of sulfur dioxide per MM
Btu actual heat input from each boiler and a daily average not to exceed eight
hundred twenty-eight pounds of sulfur dioxide per hour from all three
boilers.
(2) Boiler number D (OEPA
source number B004); a maximum of 2.45 pounds of sulfur dioxide per MM Btu
actual heat input and a daily average not to exceed one thousand fifty-six
pounds of sulfur dioxide per hour.
(3) Boiler numbers 1 and 2 (OEPA source
numbers B005 and B006); a maximum of
1.64
pounds of sulfur dioxide per MM Btu actual heat input from each boiler and a
daily average not to exceed three hundred fifteen pounds of sulfur dioxide per
hour from both boilers.
(4) Boiler
number 3 (OEPA source number B007); a maximum of 2.39 pounds of sulfur dioxide
per MM Btu actual heat input and a daily average not to exceed six hundred
eighty-six pounds of sulfur dioxide per hour.
(5) 84 inch hot slab mill furnace numbers 1,
2 and 3 (OEPA source numbers P046, P047 and P048); a maximum of 1.26 pounds of
sulfur dioxide per MM Btu actual heat input from each furnace and a daily
average not to exceed one thousand three hundred sixty-five pounds of sulfur
dioxide per hour from all furnaces.
(6) 84 inch north and south anneal furnaces
(OEPA source numbers P049 and P050); a maximum of 0.024 pound of sulfur dioxide
per MM Btu actual heat input from each unit.
(7) Basic oxygen furnace shop number 1, #1
BOF #1 vessel and #1 BOF #2 vessel (OEPA source numbers P905 and P906); from
the combustion of coke oven gas containing hydrogen sulfide, a maximum of
twenty grains of hydrogen sulfide per one hundred dry standard cubic feet of
coke oven gas.
(8) Casthouses for
blast furnace numbers C-5 and C-6 (OEPA source numbers P903 and P904); from the
combustion of coke oven gas containing hydrogen sulfide, a maximum of three
hundred ninety grains of hydrogen sulfide per one hundred dry standard cubic
feet of coke oven gas, and the daily average not to exceed thirty-three pounds
of sulfur dioxide per hour from the casthouses for either blast
furnace.
(9) Stoves for blast
furnace numbers C-5 and C-6 (OEPA source numbers P903 and P904); from the
combustion of coke oven gas containing hydrogen sulfide, a maximum of three
hundred ninety grains of hydrogen sulfide per one hundred dry standard cubic
feet of coke oven gas, and the daily average not to exceed fifty-three pounds
of sulfur dioxide per hour from the stoves for either blast furnace.
(10) [Reserved.]
(11) [Reserved.]
(12) [Reserved.]
(13) In addition to the provisions of
paragraphs (O)(1), (O)(2), and (O)(14) of this rule, powerhouse number 1,
comprised of boiler numbers A to D (OEPA source numbers B001 to B004), shall be
limited to the emission of sulfur dioxide not to exceed a daily average of one
thousand two hundred fifty-eight pounds of sulfur dioxide per hour from all
boilers.
(14) In addition to the
provisions of paragraphs (O)(1) to (O)(4), and (O)(13) of this rule, powerhouse
numbers 1 and 3, comprised of boiler numbers A to D and 1 to 3 (OEPA source
numbers B001 to B007), shall be limited to the emission of sulfur dioxide not
to exceed a daily average of one thousand nine hundred fifty-eight pounds of
sulfur dioxide per hour from all boilers.
(15) [Reserved.]
(16) From the combustion of fuel oil at any
source during any calendar day when coke oven gas is combusted at the facility,
a maximum of 0.525 pounds of sulfur per MM Btu heat content.
(P) [Reserved.]
(Q) [Reserved.]
(R) [Reserved.]
(S) [Reserved.]
(T) [Reserved]
(U) [Reserved.]
(V)
The "Medical
Center Company" (OEPA premise number 1318003059) or any subsequent owner or
operator of the "Medical Center Company, 2250 Circle Drive, Cleveland, Ohio"
shall not cause or permit the emission of sulfur dioxide from boiler numbers 1N
and 2N (OEPA source numbers B003 and B004) to exceed a maximum of 4.6 pounds of
sulfur dioxide per MM Btu actual heat input from each boiler.
[Reserved.]
(W) [Reserved.]
(X) [Reserved.]
(Y) [Reserved.]
(Z) [Reserved.]
(AA) [Reserved.]
(BB) [Reserved.]
(CC) The "
GE
Lighting
Consumer Lighting (U.S.) LLC -
Nela Park" (OEPA premise number 1318182623) or any subsequent owner or operator
of the "
GE Lighting
Consumer Lighting (U.S.) LLC - Nela Park, 1975 Noble
Road, Cleveland, Ohio" shall not cause or permit the emission of sulfur dioxide
from boiler numbers 1 and 4 (OEPA source numbers B001 and B004) to exceed a
maximum of 1.6 pounds of sulfur dioxide per MM Btu actual heat input from each
boiler.
(DD) [Reserved.]
(EE) [Reserved.]
(FF) [Reserved.]
(GG) [Reserved.]
(HH) [Reserved.]
(II) The "General Motors LLC - Parma
Plant" (OEPA premise number 1318451029) or any subsequent owner or operator of
the "General Motors LLC - Parma Plant, 5400 Chevrolet Blvd., Parma, Ohio" shall
not cause or permit the emission of sulfur dioxide from boiler numbers 1 and 2
(OEPA source numbers B001 and B002) to exceed a maximum of 1.53 pounds of
sulfur dioxide per MM Btu actual heat input from each boiler.