Ohio Admin. Code 3745-18-82 - Stark county emission limits
(A) No owner or operator of a facility in
Stark county, unless otherwise specified in this rule, shall cause or permit
the emission of sulfur dioxide from any stack in excess of the following rates:
(1) For fossil fuel-fired steam generating
units between ten and sixty MM Btu per hour total rated heat input capacity,
the emission rate in pounds of sulfur dioxide per MM Btu actual heat input
shall be calculated by the following equation:
EL = 18.48 Qm- 0.4886
where:
Qm is the total rated capacity of heat input in MM Btu per hour, and
EL is the allowable emission rate in pounds of sulfur dioxide per MM Btu actual heat input.
(2) For fossil fuel-fired steam generating
units equal to or greater than sixty MM Btu per hour total rated heat input
capacity, 2.50 pounds of sulfur dioxide per MM Btu actual heat input.
(3) No owner or operator of any process
equipment shall cause or permit the emission of sulfur dioxide from any stack
in excess of 80.0 pounds of sulfur dioxide per ton of actual process weight
input.
(B) The "Canton
Drop Forge" (OEPA premise number 1576000073) or any subsequent owner or
operator of the "Canton Drop Forge" facility located
at
, 4575 Southway Street Southwest,
Canton, Ohio" shall not cause or permit the
emission of sulfur dioxide from the following sources to exceed the amounts
indicated and the units shall not exceed the operating limits indicated:
(1) [Reserved.]
(2) [Reserved.]
(3) For boiler numbers 2 and 3 (OEPA source
numbers B002 and B003); a maximum of 2.5 pounds of sulfur dioxide per MM Btu
actual heat input from each boiler.
(4) The total fuel oil consumption by all
forge-shop furnaces shall not exceed seven hundred seventy-five gallons per
hour, eighteen thousand six hundred gallons per day and six million seven
hundred eighty-nine thousand gallons per year. [Forge-shop furnaces include
emissions units P001 to P007, P009, P010, P016, and P041.]
(5) The sulfur content for any fuel oil used
in the forge-shop furnaces shall not exceed 0.05 per cent by weight.
(C) [Reserved.]
(D) [Reserved.]
(E) The "Marathon Petroleum Company LP -
Canton Refinery" (OEPA premise number 1576002006) or any subsequent owner or
operator of the "Marathon Petroleum Company LP - Canton Refinery" facility located at
, 2408 Gambrinus Road, Canton, Ohio" shall not cause or permit the emission of sulfur
dioxide from the following sources to exceed the amounts indicated and shall
operate said sources in the manner specified:
(1)
Guard case heater 4-2-B-1 |
(OEPA source number B016), and |
ISO stripper heater 4-27-B-1 |
(OEPA source number B021); |
A maximum of 0.025 pounds of sulfur dioxide per MM Btu actual heat input from each unit.
(2) A maximum 1.0 pounds of sulfur dioxide
per MM Btu actual heat input for all process heaters and fossil fuel-fired
steam-generating units unless otherwise specified in this paragraph.
(3) Number 12 boiler 4-16-B-12 (OEPA source
number B027).
(4)
[Reserved.]
(5) FCC (OEPA source
number P002); a maximum of 0.62 pounds of sulfur dioxide per one thousand
pounds of fresh feed.
(F) The "Greif Packaging, LLC" (OEPA premise
number 1576000431) or any subsequent owner or operator of the "Greif Packaging,
LLC" facility located at
, 9420 Warmington Rd. SW, Massillon, Ohio" shall not cause or permit the emission of sulfur
dioxide from any stack at this facility in excess of 0.50 pound of sulfur
dioxide per MM Btu actual heat input.
(G) [Reserved.]
(H) [Reserved.]
(I) [Reserved.]
(J) [Reserved.]
(K) [Reserved.]
(L) [Reserved.]
(M) [Reserved.]
(N) [Reserved.]
(O) The "Timken Steel Corporation - Gambrinus
Steel Plant" (OEPA premise number 1576222000), the "Timken Steel Corporation -
Faircrest Steel Plant" (OEPA premise number 1576222001), and the "Timken Steel
Corporation - Harrison Steel Plant" (OEPA premise number 1576222002) or any
subsequent owner or operator of the "Timken Steel Corporation - Gambrinus Steel
Plant", the "Timken Steel Corporation - Faircrest Steel Plant", or the "TimkenSteel
Timken
Steel Corporation -Harrison Steel Plant"
facilities located on
, Dueber Avenue,
S.W., Canton, Ohio" shall not cause or permit the
emission of sulfur dioxide to exceed 0.67 pounds of sulfur dioxide per MM Btu
actual heat input for fossil fuel-fired steam-generating units.
(P) [Reserved.]
(Q) [Reserved.]
(R) [Reserved.]
(S) [Reserved.]
(T) The "Republic Steel-Massillion
Steel-Massillon " (OEPA premise number 1576130697) or
any subsequent owner or operator of the "Republic Steel-Massillion
Steel-Massillon
" facility
located at
, 401 Rose Avenue, Southeast,
Massillon, Ohio" shall not cause or permit the
emission of sulfur dioxide from any fossil-fuel fired steam generating unit
stack in excess of 4.40 pounds of sulfur dioxide per MM Btu actual heat
input.
Notes
Promulgated Under: 119.03
Statutory Authority: 3704.03(E)
Rule Amplifies: 3704.03(A), 3704.03(E)
Prior Effective Dates: 12/28/1979, 01/23/2006, 12/08/2007, 04/03/2011, 02/16/2017
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.