Ohio Admin. Code 3745-256-55 - Sampling connection systems - equipment leaks
(A)
Each sampling
connection system shall be equipped with a closed-purge, closed-loop, or
closed-vent system. This system shall collect the sample purge for return to
the process or for routing to the appropriate treatment system. Gases displaced
during filling of the sample container are not required to be collected or
captured.
(B)
Each closed-purge, closed-loop, or closed-vent system
as required in paragraph (A) of this rule shall:
(1)
Return the purged
process fluid directly to the process line; or
(2)
Collect and
recycle the purged process fluid; or
(3)
Be designed and
operated to capture and transport all the purged process fluid to a waste
management unit that complies with the applicable requirements of rules
3745-256-85 to
3745-256-87 of the
Administrative Code or a control device that complies with the requirements of
rule 3745-256-60 of the
Administrative Code.
(C)
In-situ sampling
systems and sampling systems without purges are exempt from the requirements of
paragraphs (A) and (B) of this rule.
Notes
Five Year Review (FYR) Dates: Exempt
Promulgated Under: 119.03
Statutory Authority: 3734.12
Rule Amplifies: 3734.12