Ohio Admin. Code 3745-51-194 - General operating requirements - tank systems
(A)
Hazardous
secondary materials or treatment reagents shall not be placed in a tank system
if the hazardous secondary materials or treatment reagents could cause the
tank, the tank's ancillary equipment, or the containment system to rupture,
leak, corrode, or otherwise fail.
(B)
The
remanufacturer or other person who stores or treats the hazardous secondary
material shall use appropriate controls and practices to prevent spills and
overflows from tank or containment systems, including, at a minimum:
(1)
Spill prevention
controls (e.g., check valves, dry disconnect couplings);
(2)
Overfill
prevention controls (e.g., level sensing devices, high level alarms, automatic
feed cutoff, or bypass to a standby tank); and
(3)
Maintenance of
sufficient freeboard in uncovered tanks to prevent overtopping by wave or wind
action or by precipitation.
(C)
The
remanufacturer or other person who stores or treats the hazardous secondary
material shall comply with the requirements of rule
3745-51-196 of the
Administrative Code if a leak or spill occurs in the tank
system.
Notes
Five Year Review (FYR) Dates: Exempt
Promulgated Under: 119.03
Statutory Authority: 3734.12
Rule Amplifies: 3734.12