Okla. Admin. Code § 165:32-5-9 - Signals, signal poles and switch stands

Current through Vol. 39, No. 14, April 01, 2022

(a) Signals and switch stands 3 feet high or less. Side clearances at signals and switch stands shall be 6 feet when said signals and switch stands are 3 feet high, or less, above top of rail when located between tracks, or where not practical to provide clearances otherwise prescribed in this Subchapter.
(b) Signals, signal poles and switch stands over 3 feet. Signals, signal poles and switch stands which stand higher than 3 feet above top of rail shall have all the portions thereof, which exceed higher than 4 feet above top of rail and less than 16 feet above top of rail, be located no less than 8 feet 6 inches from center of track. Those portions below 4 feet and over 16 feet shall not exceed the minimum clearances described above.

Notes

Okla. Admin. Code § 165:32-5-9
Added at 12 Ok Reg 2107, eff 7-1-95

The following state regulations pages link to this page.