Okla. Admin. Code § 252:100-37-42 - Permit-by-rule requirements
(a) An owner or
operator shall submit annual emission inventory reports and meet the
requirements of
252:100-37-5,
regarding operation and maintenance, and
252:100-37-38,
regarding pumps and compressors.
(b) No owner or operator shall build or
install a new stationary VOC storage vessel with a capacity of 400 gal (1.5
m3) or greater unless it is equipped with a
permanent submerged fill pipe as defined in
252:100-37-2.
(c) No owner or operator shall build or
install a stationary VOC loading facility unless each loading pipe is equipped
with a system for submerged filling of tank trucks or trailers which is
installed and operated to maintain a 97 percent submergence factor.
(d) The owner or operator of a vessel with a
storage capacity greater than 10,567 gal (40 m3)
shall maintain records on site of the dimensions of the storage vessel and an
analysis showing the capacity.