Or. Admin. Code § 333-016-0050 - Method for Determining Flashpoint of Extremely Flammable Contents of Self-Pressurized Containers
The apparatus used in the Tagliabue Open-Cup Flashpoint
Apparatus as described in OAR
333-016-0035. Some means such as
dry ice in an open container is used to chill the pressurized container. The
container, the flash cup, and the bath solution of the apparatus (brine or
glycol may be used) are chilled to a temperature of about 25 degrees Fahrenheit
below zero. The chilled container is punctured to exhaust the propellant. The
chilled formulation is transferred to the