S.C. Code Regs. § 8-1227 - IRC R802.10.1 Wood Truss Design
Truss design drawings, prepared in conformance to Section R802.10 shall be provided to the building official at the time of their inspection. Truss design drawings shall be provided with the shipment of trusses delivered to the job site. Truss design drawings shall include, at a minimum, the following information:
1.
Slope or depth, span and spacing.
2. Location of all joints.
3. Required bearing widths.
4. Design loads as applicable.
4.1. Top chord live load (as determined from
Section R301.6).
4.2. Top chord
dead load.
4.3. Bottom chord live
load.
4.4. Bottom chord dead
load.
4.5. Concentrated loads and
their points of application.
4.6.
Controlling wind and earthquake loads.
5. Adjustments to lumber and joint connector
design values for conditions of use.
6. Each reaction force and
direction.
7. Joint connector type
and description such as size, thickness or gage and the dimensioned location of
each joint connector except where symmetrically located relative to the joint
interface.
8. Lumber size, species
and grade for each member.
9.
Connection requirements for:
9.1. Truss to
girder-truss.
9.2. Truss ply to
ply.
9.3. Field
splices.
10. Calculated
deflection ratio and/or maximum description for live and total load.
11. Maximum axial compression forces in the
truss members to enable the building designer to design the size, connections
and anchorage of the permanent continuous lateral bracing. Forces shall be
shown on the truss design drawing or on supplemental documents.
12. Required permanent truss member bracing
location.
Notes