Tenn. Comp. R. & Regs. 1200-03-25-.07 - MONITORING REQUIREMENTS

The secondary chamber or afterburner temperature shall be continuously monitored and recorded. Sensors shall be installed, maintained, and operated such that the flames from the burners do not impinge upon the sensors. The secondary chamber temperature shall be measured at or beyond the chamber exit. The temperature sensing device shall have an accuracy that is ±25ºF over its operating range. The recorders must have a minimum chart speed of one (1) inch per hour for strip chart recorders and a maximum of 24 hours per chart for circular recorders.