12 Va. Admin. Code § 5-421-2520 - Backflow prevention
A.
Except as specified in subsections B, C, and D of this section, a direct
connection may not exist between the sewage system and a drain originating from
equipment in which food, portable equipment, or utensils are
placed.P
B. Subsection A of this section does not
apply to floor drains that originate in refrigerated spaces that are
constructed as an integral part of the building.
C. If allowed by law, a warewashing machine
may have a direct connection between its waste outlet and a floor drain when
the machine is located within five feet (1.5 meters) of a trapped floor drain
and the machine outlet is connected to the inlet side of a properly vented
floor drain trap.
D. If allowed by
law, a warewashing or culinary sink may have a direct connection.
Notes
Statutory Authority: §§ 35.1-11 and 35.1-14 of the Code of Virginia.