12 Va. Admin. Code § 5-590-1004 - Ozonation
A. Ozone may be
considered as a pre-oxidant to control tastes and odors, reduce color, oxidize
iron and manganese, reduce DBPPs, and used for primary disinfection. Where
ozone is used, consideration shall be given to the level of bromide and
formation of brominated byproducts.
B. Ozone systems are typically comprised of
four basic subsystems: ozone generation, feed gas preparation, ozone
contactors, and off-gas disposal.
C. The PER shall evaluate water and gas flow
rates, oxygen source, generator selection and sizing, contactor design,
treatment process location, exhaust gas collection and destruction, and
operator requirements.
D.
Treatability studies using bench-scale or pilot-scale tests may be required as
part of the PER to address the following:
1.
Alternate points of ozone application;
2. Ozone demand tests, applied dose,
transferred dose, and decay rates; and
3. Ozone byproducts, including bromide and
bromate analyses.
E.
Ozone systems shall be granted disinfection credit for Giardia lamblia,
Cryptosporidium, and viruses, in accordance with
12VAC5-590-401 E
7 and
12VAC5-590-500, provided that they
meet the requirements of this section.
1.
Ozone residual levels shall be monitored continuously and recorded. For
waterworks that claim inactivation credit for ozone, a minimum of two
dedicated, online monitors per ozone contactor shall be provided. The location
of the monitors shall be acceptable to the department. A portable ozone monitor
shall be provided as a backup.
2.
Ozone systems using multiple, consecutive contact chambers with gaseous ozone
injected in the initial chambers, shall be designed to measure the ozone
residual and compute log inactivation of Giardia and virus using the
CeffluentT10 Method or the Log
Integration CT10 Method, as described in the "Long Term
2 Enhanced Surface Water Treatment Rule Toolbox Guidance Manual," EPA Office of
Water (4606), EPA 815-R-09-016, April 2010.
3. Sampling lines shall be designed to
minimize the reaction time (typically less than 10 seconds conveyance
time).
F. Alarms shall be
provided for ozone process control safety. Automatic shutdown features shall be
considered.