An operator shall:
(1) Provide TWH dwelling units, including
common facilities, that meet the following requirements:
(a)Protect against the elements;
(b)The State Building Code, chapter 19.27 RCW
or the TWH construction standard, chapter
246-359 WAC; and
(c) State and local ordinances, codes, and
regulations when applicable.
(2)Prevent condensation in dwelling units and
common facilities to the degree that it does not contribute to a health risk or
safety issue to occupants.
(3)Prevent mold in dwelling units and common
facilities.
(4)Provide a locking
mechanism on the exterior door(s) of each family shelter. The mechanism must
not prevent egress and must be easily opened from the inside without use of a
key or special knowledge.
(5)Provide a locking mechanism on all bedroom
doors, excluding doors to bedrooms housing more than fifteen occupants. The
mechanism must not prevent egress and must be easily opened from the inside
without use of a key or special knowledge.
(6)Provide a locking mechanism on:
(a)Each toilet stall door, if provided;
and
(b)Each shower stall door, if
provided.
(7) Identify
each dwelling unit and space used for shelter by posting a number at each
site.
(8) Maintain buildings in
good repair and sanitary condition.
(9) Comply with all applicable state and
federal laws and rules for lead-based paint.
(10) Provide exits that are unobstructed and
remain free of any material or matter where its presence would obstruct or
render the exit hazardous.
(11)
Provide habitable rooms with:
(a) Windows
that equal at least one-tenth of the total floor space; and
(b) At least one-half of each window which
can be opened to the outside for ventilation; or
(c)Mechanical ventilation in accordance with
applicable standards from the American Society of Heating, Refrigerating, and
Air-conditioning Engineers (ASHRAE).
(12) Ensure each room used for sleeping
purposes has:
(a) At least fifty square feet
of floor space for each occupant not including any floor space in any portion
of a room less than seven feet from the finished floor to the finished ceiling;
and
(b) Windows that equal at least
one-tenth of the floor space within the surrounding walls of the sleeping
room.
(13)Ensure each
room in a family shelter used for sleeping and cooking purposes:
(a) Meets the requirements of subsection
(12)(b) of this section; and
(b)
(i) Has at least one hundred square feet of
floor space per temporary worker.
(ii) For a family shelter constructed or
approved for construction under chapter
246-359 WAC before January 1, 2016, one
hundred square feet of floor space per temporary worker is required by January
1, 2019. Upon the operator's request, the department of health may grant an
extension(s) for up to three additional years. Requests must:
(A)Include a schedule and work plan for
achieving compliance;
(B)Be on a
form provided by the department of health; and
(C) Be submitted to the department of health
prior to January 1, 2019.
(14) Ensure wooden floors are at least one
foot above ground-level, or meet the requirements in the State Building Code,
chapter 19.27 RCW or temporary worker housing construction standard, chapter
246-359 WAC.
(15) Provide
sixteen-mesh screening on all exterior openings.
(16) Provide and maintain screen doors on all
exterior entrances that:
(a)Have self-closing
devices; and
(b)Close without gaps
that would allow entry of pests.
(17) Install all heating, cooking, and water
heating equipment according to state and local ordinances, codes, and
regulations and maintain in a safe condition.
(18) Provide habitable rooms with equipment
capable of maintaining a temperature of at least seventy degrees Fahrenheit
during cold weather.
(19) Ensure
that all recreational vehicles and park trailers meet the requirements as
defined in this chapter.