Wash. Admin. Code § 296-56-60039 - Dockboards (bridge plates)
(1) You
must use portable and powered dockboards strong enough to carry the load
imposed.
(2) You must secure
portable dockboards in position, either by being anchored or equipped with
devices which will prevent slipping.
(3) You must design and construct powered
dockboards in accordance with commercial standards CS202-56 (1956)
Industrial Lifts and Hinged Loading Ramps published by the
United States Department of Commerce.
(4) You must provide handholds or other
effective means on portable dockboards to permit safe handling.
(5) You must provide positive protection to
prevent railroad cars from being moved while dockboards or bridge plates are in
position.