Wash. Admin. Code § 296-79-230 - Confined spaces
(1) Entry into
confined spaces must be in accordance with chapter 296-809 WAC.
(2) All equipment necessary to perform the
work, including safety equipment, must be at the confined space and must be
inspected or tested to assure that it functions properly.
(3) Protective equipment that will afford
proper protection to the employee from any condition which may arise based on
the hazard assessment, must be available either at the entrance or within the
confined space.
(4) Electrical
circuits leading into confined spaces where electrical conductive hazards exist
must be protected by a ground fault interrupter or the voltage must not exceed
24 volts.
(5) Battery operated
flashlights or lantern must be readily available for use by persons working in
areas where escape would be difficult if normal lighting system should fail.
Only explosion-proof type lights may be taken into any atmosphere which may
contain an explosive concentration.
Notes
Statutory Authority: RCW 49.17.010, 49.17.040 and 49.17.050. 99-16-083, § 296-79-230, filed 8/3/99, effective 11/3/99; Order 74-24, § 296-79-230, filed 5/6/74; Order 70-6, § 296-79-230, filed 7/10/70, effective 8/10/70.