Wash. Admin. Code § 296-79-29021 - Shredders and blowers
(1) On
manually fed broke shredders, the feed table must be of a height and distance
from the knives as to prevent the operator from reaching or falling into the
knives or the operator must be safeguarded by other acceptable means.
(2) A smooth-pivoted idler roll resting on
the stock or feed table must be provided in front of feed rolls except when
arrangements prevent the operator from standing closer than 36 inches to any
part of the feed rolls.
(3) Any
manually fed cutter, shredder, or duster must be provided with an idler roll as
specified in (2) of this section or the operator must use special hand-feeding
tools.
(4) Blowers used for
transporting materials must be provided with feed hoppers having outer edges
located not less than 48 inches from the fan.
(5) The blower discharge outlets and work
areas must be arranged to prevent material from falling on workers.