(1)
Piles of wet lap pulp (unless palletized) must be stepped back one-half the
width of the sheet for each 8 feet of pile height. Sheets of pulp must be
interlapped to make the pile secure. Pulp must not be piled over pipelines to
jeopardize pipes, or so as to cause overloading of floors, or to within 18
inches below sprinkler heads.
(2)
Piles of pulp must not be undermined when being unpiled.
(3) Floor capacities must be clearly marked
on all floors.
(4) When sprinklers
are used for fire protection in the storage area, baled paper and rags must be
stored in stable piles which do not extend into the area necessary for the
proper function of sprinkler systems.