Wash. Admin. Code § 296-817-30005 - Make sure that noise-measuring equipment meets recognized standards
|
Note: |
Make sure any dosimeter you use is Type 2 equipment that: |
|
1. Uses slow integration and A-weighting of sound levels. |
|
|
2. Has the criterion level set to 90 dB, so the dosimeter will report a constant 8-hour exposure at 90 dBA as a 100% dose. |
|
|
3. Has the threshold level set at 80 dB, so the dosimeter will register all noise above 80 dB. |
|
|
4. Uses a 5 dB exchange rate for averaging of noise levels over the sample period. |
|
Note: |
1. You may conduct dosimetry using an exchange rate less than 5 dB and compare the results directly to the noise evaluation criteria in Table 1. |
|
2. For measuring impulse and impact noise you may also use a sound level meter set to measure maximum impulse C-weighted sound levels or peak C-weighted sound levels. |
Notes
Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. 03-11-060, § 296-817-30005, filed 5/19/03, effective 8/1/03.