Wash. Admin. Code § 296-870-30025 - Reshackling and resocketing wire ropes

(1) You must make sure the nondrum ends of hoisting wire ropes are reshackled or, if the rope uses poured socket fastenings, resocketed at intervals not exceeding twenty-four months.
(2) You must make sure enough rope is cut from the end of the rope during reshackling or resocketing to remove any damaged or fatigued portions.
(3) You must make sure resocketed ropes meet the requirements of Suspension wire ropes and rope connections, WAC 296-870-70085.
(4) You must make sure limit switches affected by resocketed ropes are reset if necessary.