Wash. Admin. Code § 296-878-20005 - Select appropriate rope descent systems
(1) You must make sure the rope descent
system is designed, used, and maintained according to:
(a) ANSI/IWCA 1-14.1-2001;
(b) The manufacturer's
instructions.
(2) You
must make sure the rope descent system has been manufactured and is intended to
be used for window cleaning.
Note: Equipment that is designed or labeled for recreational use or rescue use only is prohibited for use in window-cleaning operations.
(3) You must
make sure the rope descent system components are compatible and have a minimum
tensile strength of five thousand pounds. This does not apply to the
seatboard.
(4) You must make sure
the rope descent system has specific use instructions for each
component.
Notes
Statutory Authority: RCW 49.17.010, 49.17.040, 49.17.050, and 49.17.060. 02-22-027, § 296-878-20005, filed 10/28/02, effective 1/1/03.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.