Chapter 246-359 - Temporary worker housing construction standard
- § 246-359-001 - Purpose and scope
- § 246-359-005 - Applicability
- § 246-359-010 - Definitions
- § 246-359-020 - Powers and duties of the department of health
- § 246-359-030 - Cooperation with the department of health-Right of entry
- § 246-359-040 - Appeals
- § 246-359-050 - Minor variances to the TWH construction standard
- § 246-359-060 - Architect or engineer of record and plan submittal responsibilities
- § 246-359-070 - Application and construction documents required for plan review
- § 246-359-080 - Plan review approval and expiration of plan approval
- § 246-359-090 - Issuing and maintaining a construction permit
- § 246-359-100 - Expiration and extension of construction permits
- § 246-359-110 - Construction without a permit
- § 246-359-120 - Required inspections
- § 246-359-130 - Stop work orders
- § 246-359-140 - Certificate of completion
- § 246-359-150 - Site requirements
- § 246-359-160 - TWH minimum floor area and ceiling height
- § 246-359-170 - Wood framed construction and concrete masonry unit (CMU) general limitations
- § 246-359-180 - Concrete footings and foundations for wood framed construction
- § 246-359-200 - Wood framed construction
- § 246-359-210 - Treated wood foundations for wood framed construction
- § 246-359-220 - Floor framing for wood framed construction
- § 246-359-230 - Wall framing for wood framed construction
- § 246-359-240 - Exterior wall covering for wood framed construction
- § 246-359-250 - Roof framing for wood framed construction and concrete masonry units (CMU)
- § 246-359-300 - Ceiling framing for wood framed construction and concrete masonry units (CMU)
- § 246-359-310 - Roof sheathing for wood framed construction and concrete masonry units
- § 246-359-320 - Roof covering materials for wood framed construction and concrete masonry units (CMU)
- § 246-359-330 - Roof framing ventilation for wood framed construction and concrete masonry units (CMU)
- § 246-359-340 - Nailing schedule wood framed construction and concrete masonry units
- § 246-359-350 - Roof connections for concrete masonry units (CMU)
- § 246-359-400 - Concrete masonry unit (CMU)
- § 246-359-405 - Concrete masonry units (CMU) materials
- § 246-359-410 - Foundations and footings for concrete masonry units (CMU) walls
- § 246-359-420 - Placing of concrete masonry units (CMU)
- § 246-359-430 - Floors for concrete masonry units (CMU)
- § 246-359-440 - Walls of concrete masonry units (CMU)
- § 246-359-500 - Window construction requirements
- § 246-359-510 - Door requirements
- § 246-359-520 - Door landings, stairways and guardrails
- § 246-359-530 - Interior finishes
- § 246-359-540 - Lighting and electrical
- § 246-359-550 - Smoke detectors and carbon monoxide detectors
- § 246-359-560 - Plumbing
- § 246-359-565 - Food-handling and eating facilities
- § 246-359-570 - Mechanical installations
- § 246-359-575 - Energy and ventilation and indoor air quality requirement exemptions
- § 246-359-580 - Heating, insulation, and air conditioning
- § 246-359-590 - Liquid petroleum gas (LP-gas) storage tanks
- § 246-359-600 - Alternate construction
- § 246-359-650 - Tents
- § 246-359-700 - Approval of factory assembled structures (FAS)
- § 246-359-710 - Installation of factory assembled structures (FAS)-Except for manufactured homes
- § 246-359-720 - Installation requirements for manufactured homes
- § 246-359-730 - Manufactured home installers
- § 246-359-740 - Drain connector to factory assembled structures (FAS)
- § 246-359-750 - Water connector to factory assembled structures (FAS)
- § 246-359-760 - Gas connections to factory assembled structures (FAS)
- § 246-359-800 - DOSH requirements affecting building TWH
- § 246-359-990 - Fees
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.