Wis. Admin. Code Public Service Commission § PSC 135.713 - Transmission lines: permanent field repair of imperfections and damages addition [49 CFR 192.713]
Current through March 28, 2022
After 49 CFR 192.713(a) (2), insert:
(3w) Gouges and grooves of
lesser depth than 10% of the nominal wall thickness of the pipe may be removed
by grinding out to a smooth contour provided the grinding does not reduce the
remaining wall thickness to less than the minimum prescribed by 49 CFR 192 for
the conditions of use.
Notes
The following state regulations pages link to this page.
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.