10 CFR 71.61 - Special requirements for Type B packages containing more than 10 5 A2.

§ 71.61 Special requirements for Type B packages containing more than 10 5 A2.

A Type B package containing more than 105A2 must be designed so that its undamaged containment system can withstand an external water pressure of 2 MPa (290 psi) for a period of not less than 1 hour without collapse, buckling, or inleakage of water.

[ 69 FR 3795, Jan. 26, 2004]

Title 10 published on 19-May-2018 04:00

The following are ALL rules, proposed rules, and notices (chronologically) published in the Federal Register relating to 10 CFR Part 71 after this date.

  • 2017-11-15; vol. 82 # 219 - Wednesday, November 15, 2017
    1. 82 FR 52823 - Miscellaneous Corrections
      GPO FDSys XML | Text
      NUCLEAR REGULATORY COMMISSION
      Final rule.
      This rule is effective December 15, 2017. The material incorporated by reference was previously approved by the Director of the Federal Register.
      10 CFR Parts 2, 9, 40, 50, 61, 71, 73, and 110
The section you are viewing is cited by the following CFR sections.