No position light intensity may exceed the applicable values in the following table, except as provided in § 25.1389(b)(3).
Overlaps | Maximum intensity | |
---|---|---|
Area A (candles) | Area B (candles) | |
Green in dihedral angle |
10 | 1 |
Red in dihedral angle |
10 | 1 |
Green in dihedral angle |
5 | 1 |
Red in dihedral angle |
5 | 1 |
Rear white in dihedral angle |
5 | 1 |
Rear white in dihedral angle |
5 | 1 |
Where—
(a) Area A includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 10 degrees but less than 20 degrees; and
(b) Area B includes all directions in the adjacent dihedral angle that pass through the light source and intersect the common boundary plane at more than 20 degrees.