40 CFR § 420.97 - Effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional technology (BCT).
Except as provided in 40 CFR 125.30 through 125.32, any existing point source subject to this subpart must achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best conventional technology.
(a) Sulfuric acid pickling (spent acid solutions and rinse waters)—(1) Rod, wire and coil.
Subpart I
1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.
2 Within the range of 6.0 to 9.0.
(2) Bar, billet and bloom.
Subpart I
1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.
2 Within the range of 6.0 to 9.0.
(3) Strip, sheet and plate.
Subpart I
1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.
2 Within the range of 6.0 to 9.0.
(4) Pipe, tube and other products.
Subpart I
1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.
2 Within the range of 6.0 to 9.0.
(5) Fume scrubbers.
Subpart I
1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.
2 Within the range of 6.0 to 9.0.
(b) Hydrochloric acid pickling (spent acid solutions and rinse waters)—(1) Rod, wire and coil.
Subpart I
1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.
2 Within the range of 6.0 to 9.0.
(2) Strip, sheet and plate.
Subpart I
1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.
2 Within the range of 6.0 to 9.0.
(3) Pipe, tube and other products.
Subpart I
1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.
2 Within the range of 6.0 to 9.0
(4) Fume scrubbers.
Subpart I
1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.
2 Within the range of 6.0 to 9.0.
(5) Acid regeneration (absorber vent scrubber).
Subpart I
1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.
2 Within the range of 6.0 to 9.0.
(c) Combination acid pickling (spent acid solution and rinse waters)—(1) Rod, wire, and coil.
Subpart I
1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.
2 Within the range of 6.0 to 9.0.
(2) Bar, billet, and bloom.
Subpart I
1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.
2 Within the range of 6.0 to 9.0.
(3) Strip, sheet, and plate—continuous.
Subpart I
1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.
2 Within the range of 6.0 to 9.0.
(4) Strip, sheet and plate—batch.
Subpart I
1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.
2 Within the range of 6.0 to 9.0.
(5) Pipe, tube, and other products.
Subpart I
1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.
2 Within the range of 6.0 to 9.0.
(6) Fume scrubbers.
Subpart I
1 The limitations for oil and grease shall be applicable when acid pickling wastewaters are treated with cold rolling wastewaters.
2 Within the range of 6.0 to 9.0.