40 CFR 98.413 - Calculating GHG emissions.

§ 98.413 Calculating GHG emissions.
Link to an amendment published at 81 FR 89270, Dec. 9, 2016.

(a) Calculate the total mass of each fluorinated GHG or nitrous oxide produced annually, except for amounts that are captured solely to be shipped off site for destruction, by using Equation OO-1 of this section:

P = Mass of fluorinated GHG or nitrous oxide produced annually.
Pp = Mass of fluorinated GHG or nitrous oxide produced over the period “p”.

(b) Calculate the total mass of each fluorinated GHG or nitrous oxide produced over the period “p” by using Equation OO-2 of this section:

Where:
Pp = Mass of fluorinated GHG or nitrous oxide produced over the period “p” (metric tons).
Op = Mass of fluorinated GHG or nitrous oxide that is measured coming out of the production process over the period p (metric tons).
Up = Mass of used fluorinated GHG or nitrous oxide that is added to the production process upstream of the output measurement over the period “p” (metric tons).

(c) Calculate the total mass of each fluorinated GHG or nitrous oxide transformed by using Equation OO-3 of this section:

Where:
T = Mass of fluorinated GHG or nitrous oxide transformed annually (metric tons).
FT = Mass of fluorinated GHG fed into the transformation process annually (metric tons).
ET = The fraction of the fluorinated GHG or nitrous oxide fed into the transformation process that is transformed in the process (metric tons).

(d) Calculate the total mass of each fluorinated GHG destroyed by using Equation OO-4 of this section:

Where:
D = Mass of fluorinated GHG destroyed annually (metric tons).
FD = Mass of fluorinated GHG fed into the destruction device annually (metric tons).
DE = Destruction efficiency of the destruction device (fraction).

This is a list of United States Code sections, Statutes at Large, Public Laws, and Presidential Documents, which provide rulemaking authority for this CFR Part.

This list is taken from the Parallel Table of Authorities and Rules provided by GPO [Government Printing Office].

It is not guaranteed to be accurate or up-to-date, though we do refresh the database weekly. More limitations on accuracy are described at the GPO site.