40 CFR Appendix Table 12 to Subpart G of Part 63, Monitoring Requirements for Treatment Processes

Table 12 to Subpart G of Part 63 - Monitoring Requirements for Treatment Processes
To comply with Parameters to be monitored Frequency Methods
1. Required mass removal of Table 8 and/or Table 9 compound(s) from wastewater treated in a properly operated biological treatment unit, § 63.138(f) , and § 63.138(g) Appropriate parameters as specified in § 63.143(c) and approved by permitting authority Appropriate frequency as specified in § 63.143 and approved by permitting authority Appropriate methods as specified in § 63.143 and as approved by permitting authority.
2. Steam stripper (i) Steam flow rate; and Continuously Integrating steam flow monitoring device equipped with a continuous recorder.
(ii) Wastewater feed mass flow rate; and Continuously Liquid flow meter installed at stripper influent and equipped with a continuous recorder.
(iii) Wastewater feed temperature; or
(iv) Column operating temperature
Continuously (A) Liquid temperature monitoring device installed at stripper influent and equipped with a continuous or recorder; or
(B) Liquid temperature monitoring device installed in the column top tray liquid phase (i.e., at the downcomer) and equipped with a continuous recorder.
3. Other treatment processes or alternative monitoring parameters to those listed in item 2 of this table Other parameters may be monitored upon approval from the Administrator with the requirements specified in § 63.151(f)