40 CFR Appendix Table 40 to Subpart UUU of Part 63 - Requirements for Installation, Operation, and Maintenance of Continuous Opacity Monitoring Systems and Continuous Emission Monitoring Systems
Table 40 to Subpart UUU of Part 63—Requirements for Installation, Operation, and Maintenance of Continuous Opacity Monitoring Systems and Continuous Emission Monitoring Systems
As stated in § 63.1572(a)(1) and (b)(1), you shall meet each requirement in the following table that applies to you.
| This type of continuous opacity or emission monitoring system . . . | Must meet these requirements . . . |
|---|---|
| 1. Continuous opacity monitoring system | Performance specification 1 (40 CFR part 60, appendix B). |
| 2. PM CEMS; this monitor must include an O |
The requirements in 40 CFR 60.105a(d). |
| 3. CO continuous emission monitoring system | Performance specification 4 (40 CFR part 60, appendix B); span value of 1,000 ppm; and procedure 1 (40 CFR part 60, appendix F) except relative accuracy test audits are required annually instead of quarterly. |
| 4. CO continuous emission monitoring system used to demonstrate emissions average under 50 ppm (dry basis) | Performance specification 4 (40 CFR part 60, appendix B); and span value of 100 ppm. |
| 5. SO |
Performance specification 2 (40 CFR part 60, appendix B); span value of 500 ppm SO |
| 6. Reduced sulfur and O |
Performance specification 5 (40 CFR part 60, appendix B), except calibration drift specification is 2.5 percent of the span value instead of 5 percent; span value is 450 ppm reduced sulfur, or if using Equation 1 of 40 CFR 60.102a(f)(1)(i), span value of two times the limit at the highest O |
| 7. Instrument with an air or O |
Performance specification 5 (40 CFR part 60, appendix B); span value of 375 ppm SO |
| 8. TRS continuous emission monitoring system for sulfur recovery unit; this monitor must include an O |
Performance specification 5 (40 CFR part 60, appendix B). |
| 9. O |
If necessary due to interferences, locate the oxygen sensor prior to the introduction of any outside gas stream; performance specification 3 (40 CFR part 60, appendix B; and procedure 1 (40 CFR part 60, appendix F), except relative accuracy test audits, are required annually instead of quarterly. |
[80 FR 75317, Dec. 1, 2015]