40 CFR Appendix Table 7 to Subpart U of Part 63 - Operating Parameters for Which Monitoring Levels Are Required To Be Established for Continuous and Batch Front-End Process Vents and Aggregate Batch Vent Streams
Table 7 to Subpart U of Part 63—Operating Parameters for Which Monitoring Levels Are Required To Be Established for Continuous and Batch Front-End Process Vents and Aggregate Batch Vent Streams
| Control/recovery device | Parameters to be monitored | Established operating parameter(s) |
|---|---|---|
| Thermal incinerator | Firebox temperature | Minimum temperature. |
| Thermal oxidizers used for vents in chloroprene service | Combustion chamber temperature | Minimum temperature. |
| Thermal oxidizers used for vents in chloroprene service | Flue gas flow rate | Maximum flue gas flow rate. |
| Catalytic incinerator | Temperature upstream and downstream of the catalyst bed | Minimum upstream temperature; and minimum temperature difference across the catalyst bed. |
| Boiler or process heater | Firebox temperature | Minimum temperature. |
| Scrubber for halogenated vents | pH of scrubber effluent; and scrubber liquid and gas flow rates [§ 63.489(b)(4)(ii)] | Minimum pH; and minimum liquid/gas ratio. |
| Absorber | Exit temperature of the absorbing liquid; and exit specific gravity of the absorbing liquid | Maximum temperature; and maximum specific gravity. |
| Condenser | Exit temperature | Maximum temperature. |
| Carbon adsorber | Total regeneration steam flow or nitrogen flow, or pressure (gauge or absolute) a during carbon bed regeneration cycle; and temperature of the carbon bed after regeneration (and within 15 minutes of completing any cooling cycle(s)) | Maximum flow or pressure; and maximum temperature. |
| Sorbent injection | Sorbent injection rate | Minimum injection rate. |
| Sorbent injection | Carrier gas flow rate | Minimum carrier gas flow rate. |
| Other devices (or as an alternate to the above) b | HAP concentration level or reading at outlet of device | Maximum HAP concentration or reading. |
a 25 to 50 mm (absolute) is a common pressure level obtained by pressure swing absorbers.
b Concentration is measured instead of an operating parameter.
[89 FR 43267, May 16, 2024]