Ariz. Admin. Code § R11-1-273 - Initiating Blasts
A. When fuse is
used, the blast cap shall be securely attached to the safety fuse with a
standard ring-type (or other approved) cap crimper.
B. No primers shall be assembled or fuse
capped closer than 50 feet from any magazine.
C. Only wooden or non-sparking tools shall be
used for making holes in a cartridge of explosives.
D. Explosives shall not be extracted from a
hole that has once been charged or has misfired unless it is impossible to
detonate the unexploded charge by insertion of a fresh additional
primer.
E. If there are any
misfires while using cap and fuse, all persons shall remain away from the
charge for at least one hour. On electrical misfires, all persons shall remain
away from the charge for at least 15 minutes. Electrical misfires shall be
handled under the direction of the person in charge of the blasting and all
wires shall be carefully traced and search made for unexploded
charges.
F. Blasters, when testing
circuits to charged holes, shall use only blasting galvanometers designed for
this purpose.
G. Only the man who
makes the leading wire connections in electrical firing shall fire the shot.
All connections should be made progressively from borehole back to the source
of firing current, and the leading wires shall remain shorted and not be
connected to the blasting machine or other source of current until the charge
is to be fired.
H. Blasts in shafts
or winzes shall be initiated from a safe location outside the shaft or
winze.
I. When blasting
electrically, the electric blasting cap leg wire shunt shall not be removed
from the leg wires until loading operations have been completed.
J. When firing from 1 to 15 blastholes with
safety fuse ignited individually using hand-held lighters, the fuses shall be
of such lengths to provide the minimum burning time specified in the following
table for a particular size round:
|
Number of Holes in a Round |
Minimum Burning Time, Minutes |
|
1 |
2 |
|
2-5 |
2 2/3 |
|
6-10 |
3 1/3 |
|
11-15 |
5 |
In no case shall any 40-second-per-foot safety fuse less than 36 inches long or any 30-second-per-foot safety fuse less than 48 inches long be used.
K. Not over 15
fuses shall be spit by each blaster if being individually ignited. At least two
men shall be present when lighting fuses, and no man shall light more than 15
individual fuses. To avoid an unsafe delay in the operation, all men shall
carry out the lighting of fuses simultaneously. If more than 15 holes per man
are to be fired, igniter cord and connectors or electric blasting shall be
used.
L. No fuse shall be used that
burns faster than one foot in 30 seconds or slower than one foot in 55 seconds.
The burning rate of every shipment of fuse received at a mine shall be
determined. If a shipment of fuse lasts more than 60 days, the burning rate
must be rechecked each 60 days. The burning rate of the safety fuse in use at
any time shall be measured, posted in conspicuous locations, and brought to the
attention of all men concerned with blasting.
M. Fuse shall be ignited with hot wire
lighters, lead spitters, igniter cord or other such approved type device as
designed for this purpose. Carbide lights shall not be used to light
fuses.
N. Where electric blasting
is to be performed, electric circuits to equipment in the immediate area to be
blasted shall be de-energized before electric detonators are connected to the
blasting circuit; the power shall not be turned on until after the shots are
fired or the blast is deactivated by removing or shunting each electric
detonator.
O. Trunklines, in
multiple-row blasts initiated by detonating cord, shall make one or more
complete loops, with crossties between loops at intervals of not over 200
feet.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.