Ariz. Admin. Code § R12-7-180 - Supplementary Requirements for Storage Wells

The application for a storage well as defined in R12-7-175(B)(2) shall be prepared in accordance with R12-7-176 and shall contain the following, where applicable:

1. Information on any oil or gas production within 5 miles of each proposed well;
2. Information on the oil and gas reserves of each storage zone before starting injection, including calculations;
3. A comprehensive plan for disposition of brine and salt produced in the course of creating a solution-mined salt cavity. Cavities shall be designed and constructed in accordance with R12-7-181;
a. Surface disposition shall be subject to the rules of the Department of Water Resources and the Department of Environmental Quality;
b. Saltwater disposal wells shall be permitted in accordance with R12-7-176;
c. Surface brine reservoirs used in the operation of the storage system and disposal reservoirs shall be designed to prevent the contamination of air, fresh water, and soil;
4. A list of proposed surface and subsurface safety devices, tests, and precautions to be taken to ensure safety of the project. The operator shall install a flare or other safety system acceptable to the Commission at or near each brine pit or any other location where escape of gases is likely to occur.

Notes

Ariz. Admin. Code § R12-7-180
Former Rule 705; Amended effective September 29, 1982 (Supp. 82-5). Amended effective January 2, 1996 (Supp. 96-1).

State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.