Ariz. Admin. Code § R18-2-721 - Standards of Performance for Existing Nonferrous Metals Industry Sources
A. The provisions
of this Section are applicable to the following affected facilities:
1. Mines,
2. Mills,
3. Concentrators,
4. Crusers,
5. Screens,
6. Material handling facilities,
7. Fine ore storage,
8. Dryers,
9. Roasters, and
10. Loaders.
B. No person shall cause, allow or permit the
discharge of particulate matter into the atmosphere in any one hour from any
process source subject to the provisions of this Section in total quantities in
excess of the amounts calculated by one of the following equations:
1. For process sources having a process
weight rate of 60,000 pounds per hour (30 tons per hour) or less, the maximum
allowable emissions shall be determined by the following equation:
E = 4.10P0.67
where:
E = the maximum allowable particulate emissions rate in pounds-mass per hour.
P = the process weight rate in tons-mass per hour.
2. For process sources
having a process weight greater than 60,000 pounds per hour (30 tons per hour),
the maximum allowable emissions shall be determined by the following
equation:
E = 55.0P0.11 -40
where "E" and "P" are defined as indicated in subsection (B)(1).
C. Actual values shall be
calculated from the applicable equations and rounded off to two decimal
places.
D. For purposes of this
Section, the total process weight from all similar units employing a similar
type process shall be used in determining the maximum allowable emission of
particulate matter.
E. No person
shall cause, allow or permit to be discharged into the atmosphere from any
dryer or roaster the operating temperature of which exceeds 700°F, reduced
sulfur in excess of 10% of the sulfur entering the process as feed. Reduced
sulfur includes sulfur equivalent from all sulfur emissions including sulfur
dioxide, sulfur trioxide, and sulfuric acid.
F. The owner or operator of any mining
property subject to the provisions of this Section shall record the daily
process rates and hours of operation of all material handling
facilities.
G. A continuous
monitoring system for measuring sulfur dioxide emissions shall be installed,
calibrated, maintained and operated by the owner or operator where dryers or
roasters are not expected to achieve compliance with the standard under
subsection (E).
H. The test methods
and procedures required by this Section are as follows:
1. The reference methods in 40 CFR 60,
Appendix A, as incorporated by reference in Appendix 2 of this Chapter, shall
be used to determine compliance with the standard prescribed in this Section as
follows:
a. Method 5 for the concentration of
particulate matter and the associated moisture content;
b. Method 1 for sample and velocity
traverses;
c. Method 2 for velocity
and volumetric flow rate;
d. Method
3 for gas analysis and calculation of excess air, using the integrated sample
technique;
e. Method 6 for
concentration of SO2.
2. For Method 5, Method 1 shall be used to
select the sampling site and the number of traverse sampling points. The
sampling time for each run shall be at least 60 minutes and the minimum
sampling volume shall be 0.85 dscm (30 dscf), except that smaller sampling
times or volumes, when necessitated by process variables or other factors, may
be approved by the Director. The probe and filter holder heating systems in the
sampling train shall be set to provide a gas temperature no greater than
160°C. (320°F.).
3. For
Method 6, the sampling site shall be the same as that selected for Method 5.
The sampling point in the duct shall be at the centroid of the cross section or
at a point no closer to the walls than 1 m (3.28 ft.). For Method 6, the sample
shall be extracted at a rate proportional to the gas velocity at the sampling
point.
4. For Method 6, the minimum
sampling time shall be 20 minutes and the minimum sampling volume 0.02 dscm
(0.71 dscf) for each sample. The arithmetic mean of two samples shall
constitute one run. Samples shall be taken at approximately 30-minute
intervals.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.