Ariz. Admin. Code § R18-9-F644 - Class II; Operating, Monitoring, and Reporting Requirements
A. Operating
requirements shall, at a minimum, specify that:
1. Injection pressure at the wellhead shall
not exceed a maximum which shall be calculated so as to assure that the
pressure during injection does not initiate new fractures or propagate existing
fractures in the confining zone adjacent to the USDWs. In no case shall
injection pressure cause the movement of injection or formation fluids into an
USDW.
2. Injection between the
outermost casing protecting USDWs and the well bore shall be
prohibited.
B.
Monitoring requirements shall, at a minimum, include:
1. Monitoring of the nature of injected
fluids at time intervals sufficiently frequent to yield data representative of
their characteristics;
2.
Observation of injection pressure, flow rate, and cumulative volume at least
with the following frequencies:
a. Weekly for
produced fluid disposal operations;
b. Monthly for enhanced recovery
operations;
c. Daily during the
injection of liquid hydrocarbons and injection for withdrawal of stored
hydrocarbons; and
d. Daily during
the injection phase of cyclic steam operations; and
e. Record one observation of injection
pressure, flow rate and cumulative volume at reasonable intervals no greater
than 30 days;
3. A
demonstration of mechanical integrity pursuant to
R18-9-B613 at least once every
five years during the life of the injection well;
4. Maintenance of the results of all
monitoring until the next permit review; and
5. Hydrocarbon storage and enhanced recovery
may be monitored on a field or project basis rather than on an individual well
basis by manifold monitoring. Manifold monitoring may be used in cases of
facilities consisting of more than one injection well, operating with a common
manifold. Separate monitoring systems for each well are not required provided
the owner/operator demonstrates that manifold monitoring is comparable to
individual well monitoring.
C. Reporting requirements.
1. Reporting requirements shall at a minimum
include an annual report to the Director summarizing the results of monitoring
required under subsection (B) of this Section. Such summary shall include
monthly records of injected fluids, and any major changes in characteristics or
sources of injected fluid. Previously submitted information may be included by
reference.
2. Owners or operators
of hydrocarbon storage and enhanced recovery projects may report on a field or
project basis rather than an individual well basis where manifold monitoring is
used.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.