Ariz. Admin. Code § R18-9-J667 - Class VI; Injection Well Plugging
A. Prior to the
well plugging, the owner or operator must flush each Class VI injection well
with a buffer fluid, determine bottomhole reservoir pressure, and perform a
final external mechanical integrity test.
B. The owner or operator of a Class VI well
must prepare, maintain, and comply with a plan that is acceptable to the
Director. The requirement to maintain and implement an approved plan is
directly enforceable regardless of whether the requirement is a condition of
the permit. The well plugging plan must be submitted as part of the permit
application and must include the following information:
1. Appropriate tests or measures for
determining bottomhole reservoir pressure;
2. Appropriate testing methods to ensure
external mechanical integrity as specified in
R18-9-J664;
3. The type and number of plugs to be
used;
4. The placement of each
plug, including the elevation of the top and bottom of each plug;
5. The type, grade, and quantity of material
to be used in plugging. The material must be compatible with the carbon dioxide
stream; and
6. The method of
placement of the plugs.
C. The owner or operator must notify the
Director in writing pursuant to
R18-9-J666(5), at
least 60 days before plugging of a well. At this time, if any changes have been
made to the original well plugging plan, the owner or operator must also
provide the revised well plugging plan. The Director may allow for a shorter
notice period. Any amendments to the injection well plugging plan must be
approved by the Director, must be incorporated into the permit, and are subject
to the permit modification requirements at
R18-9-C632 or
R18-9-C633, as
appropriate.
D. Within 60 days
after plugging, the owner or operator must submit, pursuant to
R18-9-J666(5), a
plugging report to the Director. The report must be certified as accurate by
the owner or operator and by the person who performed the plugging operation,
if other than the owner or operator. The owner or operator shall retain the
well plugging report for 10 years following site closure.
Notes
State regulations are updated quarterly; we currently have two versions available. Below is a comparison between our most recent version and the prior quarterly release. More comparison features will be added as we have more versions to compare.
No prior version found.