Ariz. Admin. Code § R9-10-2226 - Physical Plant Standards
A. An
administrator shall ensure that:
1. A
nursing-supported group home is in compliance with applicable federal and state
disability laws;
2. If a
nursing-supported group home has a resident with a mobility, sensory, or other
physical impairment, documentation is available for review at the
nursing-supported group home that:
a. Is
provided by the Division; and
b.
Identifies modifications, if any, needed to the premises to ensure that the
premises are:
i. Accessible to and usable by
the resident, and
ii. Contribute to
the resident's health and safety;
3. The premises have been modified as
identified by the Division in subsection (A)(2)(b);
4. Ramps, stairs, or steps on the premises
are secured firmly to the ground or a permanent structure and have
slip-resistant surfaces; and
5. If
handrails and grab bars are installed in a nursing-supported group home,
handrails and grab bars are securely attached and stationary.
B. An administrator shall ensure
that:
1. A method of heating and cooling
maintains the nursing-supported group home between 65° F and 85° F in
areas of the nursing-supported group home occupied by residents;
2. A usable fireplace is covered by a
protective screen or covering at all times;
3. Ventilation is provided by an openable
window, air conditioning, or other mechanical device;
4. Working, safe appliances for cooling and
cooking food are provided in the nursing-supported group home that:
a. Are safety-approved;
b. If used to refrigerate food, maintain the
food at a temperature of 40° F or below at all times; and
c. If used to freeze food, maintain the food
at a temperature of 0° F or below at all times;
5. Hot water temperatures in the
nursing-supported group home are maintained between 95° F and 120° F;
and
6. Bathtubs and showers contain
slip-resistant strips, rubber bath mats, or slip-resistant surfaces.
C. An administrator shall ensure
that:
1. Electrical lighting is contained in
each room in the nursing-supported group home;
2. Electrical devices and equipment on the
premises are safety-approved, safe, and in working order;
3. Electrical outlets on the premises are
safe, covered with a faceplate, and installed in accordance with the
requirements of the local jurisdiction;
4. Any electrical outlet located within 3
feet of a water source includes a ground fault circuit interrupt
(GFCI);
5. An appliance, light, or
other device with a frayed or spliced electrical cord is not used on the
premises; and
6. An electrical
cord, including an extension cord, on the premises is not:
a. Used as a substitute for permanent
wiring,
b. Run under a rug or
carpeting,
c. Run over a nail,
or
d. Run from one room to
another.
D.
An administrator shall ensure that:
1. A
nursing-supported group home contains a safe, working plumbing
system;
2. If a nursing-supported
group home's plumbing system is connected to a non-municipal sewage disposal
system, the plumbing system and connective piping are free of visible leakage;
and
3. The premises do not contain
unfenced or uncovered wells, ditches, or holes into which an individual may
step or fall.