Ariz. Admin. Code § R9-7-515 - Locking Radiographic Exposure Devices, Storage Containers, and Source Changers
A. Except
at permanent radiographic installations governed by R9-7-539, a licensee shall
ensure that each radiographic exposure device has a lock or an outer container
with a lock designed to prevent unauthorized or accidental removal of the
sealed source from its shielded position. The licensee shall ensue that the
exposure device or its container, if applicable, is locked (and if a keyed
lock, with the key removed) if the device or container is not under the direct
surveillance of a radiographer or a radiographer's assistant. During
radio-graphic operations, the radiographer or radiographer's assistant shall
secure the sealed source assembly in the shielded position each time the source
is returned to the shielded position.
B. A licensee shall ensure that each sealed
source storage container and source changer has a lock or an outer container
with a lock designed to prevent unauthorized or accidental removal of the
sealed source from its shielded position. The licensee shall ensure that each
storage container and source changer is locked (and if a keyed lock, with the
key removed) if the storage container or source changer contains a sealed
source and is not under the direct surveillance of a radiographer or a
radiographer's assistant.