Fla. Admin. Code Ann. R. 11D-8.012 - Blood Samples - Labeling and Collection
(1) Before collecting a sample of blood, the
skin puncture area must be cleansed with an antiseptic that does not contain
alcohol.
(2) Blood samples must be
collected in a glass evacuation tube that contains a preservative such as
sodium fluoride and an anticoagulant such as potassium oxalate or EDTA
(ethylenediaminetetraacetic acid). Compliance with this section can be
established by the stopper or label on the collection tube, documentation from
the manufacturer or distributor, or other evidence.
(3) Immediately after collection, the tube
must be inverted several times to mix the blood with the preservative and
anticoagulant.
(4) Blood collection
tubes must be labeled with the following information: name of person tested,
date and time sample was collected, and initials of the person who collected
the sample.
(5) Blood samples need
not be refrigerated if submitted for analysis within seven (7) days of
collection, or during transportation, examination or analysis. Blood samples
must be otherwise refrigerated, except that refrigeration is not required
subsequent to the initial analysis.
(6) Blood samples must be hand-delivered or
mailed for initial analysis within thirty days of collection, and must be
initially analyzed within sixty days of receipt by the facility conducting the
analysis. Blood samples which are not hand-delivered must be sent by priority
mail, overnight delivery service, or other equivalent delivery
service.
(7) Notwithstanding any
requirements in chapter 11D-8, F.A.C., any blood analysis results obtained, if
proved to be reliable, shall be acceptable as a valid blood alcohol
level.
Notes
Rulemaking Authority 316.1932(1)(a)2., (f)1., 322.63(3)(a), 327.352(1)(b)3., (d) FS. Law Implemented 316.1933(2)(b), 316.1934(3), 322.63(3)(b), 327.352(1)(e), 327.353(2), 327.354(3) FS.