Fla. Admin. Code Ann. R. 40E-41.063 - Conditions for Issuance of Permits in the Western Canal 9 Basin
(1) For design purposes the 100-year, 25-year
and 10-year flood frequency elevations are established as 7.3 feet, 6.8 feet
and 6.5 feet mean sea level, respectively.
(2) For systems designed to be pumped from
fully diked areas, discharge shall be limited to three-fourths of an inch per
twenty-four hours, or the criteria in Rules
62-330.301 and
62-330.302, F.A.C., whichever is
more restrictive. In addition, no pumping shall be permitted when Canal 9
stages at pump tailwater exceed the 25-year peak elevation of 6.8 feet mean sea
level.
(3) All direct connections
to Canal 9 shall be designed to prevent lowering of the groundwater table below
elevation 2.5 feet mean sea level. All indirect connections to Canal 9 shall be
designed to prevent lowering of the groundwater table by installing the
discharge facilities at a discharge elevation no lower than six inches below
average existing ground elevation for the project. Nothing in this subsection
shall be construed to preclude the construction and operation of discharge
facilities designed to temporarily lower the groundwater table below these
elevations immediately prior to the arrival of a major storm event.
(4) Fill encroachment criteria-
(a) The volume encroached by development
between average existing ground surface and elevation 7.0 feet mean sea level
shall not exceed 2.0 feet times the total area of the property.
(b) For diked areas with on-site retention of
runoff, the area diked shall not exceed the encroachment volume specified in
paragraph (a) divided by the difference between average existing ground
elevation within the dike and elevation 5.75 feet mean sea level. This will
require all such projects on land of average elevation less than 3.75 feet mean
sea level to preserve some area outside of the dikes with no fill. The
preserved area shall be located so as to preserve natural basin flow patterns
for lands outside the dikes.
(c)
Typical development schemes using these criteria are depicted in Figure 41-2
(August 2016) [http://www.flrules.org/Gateway/reference.asp?No=Ref-07150],
incorporated by reference herein, and available at no cost by contacting the
South Florida Water Management District Clerk's Office, 3301 Gun Club Road,
West Palm Beach, FL 33406, (800)432-2045, ext. 2729 or
(561)682-2729.
Notes
Rulemaking Authority 373.044, 373.113, 373.4131 FS. Law Implemented 373.413, 373.4131, 373.416 FS.
New 9-3-81, Formerly 16K-34.06, Amended 4-20-94, 10-1-13, 8-7-16.